Description

This sensor detects the rotation speed of the input turbine. By comparing the input turbine speed signal (NT) with the counter gear speed sensor signal (NC), the ECM detects the shift timing of the gears and appropriately controls the engine torque and hydraulic pressure according to various conditions. Thus, providing smooth gear shift.

DTC No.

DTC Detection Condition

Trouble Area

P0717

ECM detects conditions (a), (b) and (c) continuously for 5 sec. or more: (1-trip detection logic)

(b) Park/neutral position switch (STAR and R) is OFF

(c) Speed sensor (NT): less than 300 rpm

• Open or short in transmission revolution sensor NT (speed sensor NT) circuit

• Transmission revolution sensor NT (speed sensor NT)

• Automatic transaxle assembly

\ iA A i

A A. A'

GN D

5 V/DIV

GN D

Reference (Using an oscilloscope):

Check the waveform between terminals NT+ and NT- of the ECM connector. Standard: Refer to the illustration.

Terminal

Tool setting

Vehicle condition

NT+ - NT-

S V/DIV, O.Sms/DIV

Vehicle speed 20 km/h (12 mph)