Inspect Shift Lock Solenoid

(a) Disconnect the solenoid connector.

(b) Connect the SLL+ (2) terminal to the battery positive (+) terminal, and the SLS- (1) terminal to the battery negative (-) terminal, and apply about 12 V between the SLL+ and SLS- terminals.

(c) Check that operation noise can be heard from the solenoid.

If the solenoid does not operate, replace the solenoid.

Terminal

Measuring Condition

Ignition switch ON

Ignition switch OFF

121110 9 8