Inspection Procedure

INSPECT AIR CONDITIONING AMPLIFIER (TEA - SGA)

(a) Remove the air conditioning amplifier with connectors still connected.

(b) Turn the ignition switch on (IG).

(c) Measure the voltage according to the value(s) in the table below.

Voltage

Tester connection

Condition

Specified condition

X1-6 (TEA) - X1-S (SGA

Ignition switch on (IG) at 0°C (32°F)

2.0 to 2.4 V

X1-6 (TEA) - X1-S (SGA

Ignition switch on (IG) at 15°C (59°F)

As the temperature increases, the voltage decreases.

Result

Result

Proceed to

NG

A

OK (Checking from the PROBLEM SYMPTOM TABLE)

B

OK (Checking from the DTC)

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

REPLACE AIR CONDITIONING AMPLIFIER

INSPECT A/C EVAPORATOR TEMPERATURE SENSOR

A/C Evaporator Temperature Sensor Front View:

E050650E03

Resistance (kQ)

Resistance (kQ)

Temperature i04143ie02

Temperature i04143ie02

(a) Remove the A/C evaporator temperature sensor.

(b) Measure the resistance according to the value(s) in table below. Resistance

Tester connection

Condition

Specified condition

1 - 2

-10°C (14°F)

7.30 to 9.10 kQ

1 - 2

-5°C (23°F)

5.65 to 6.95 kQ

1 - 2

0°C (32°F)

4.40 to 5.35 kQ

1 - 2

5°C (41 °F)

3.40 to 4.15 kQ

1 - 2

10°C (50°F)

2.70 to 3.25 kQ

1 - 2

15°C (59°F)

2.14 to 2.58 kQ

1 - 2

20°C (68°F)

1.71 to 2.05 kQ

1 - 2

25°C (77°F)

1.38 to 1.64 kQ

1 - 2

30°C (86°F)

1.11 to 1.32 kQ

NOTICE:

• Only hold the sensor at its connector. Touching the sensor may change the resistance value.

• When measuring, the sensor temperature must be the same as the ambient temperature.

HINT:

• As the temperature increases, the resistance decrease (See the graph).

• When replacing the A/C evaporator temperature sensor, the attached sub-harness should be replaced along with the sensor.

REPLACE A/C EVAPORATOR TEMPERATURE SENSOR

CHECK HARNESS AND CONNECTOR (A/C AMPLIFIER - A/C EVAPORATOR TEMPERATURE SENSOR)

(a) Disconnect the connector from the air conditioning amplifier.

(b) Disconnect the connector from the A/C evaporator temperature sensor.

(c) Measure the resistance according to the value(s) in the table below.

Resistance

Tester connection

Condition

Specified condition

X1-6 (TEA) - 1

Always

Below 1 Q

X1-5 (SGA) - 2

Always

Below 1 Q

X1-6 (TEA) - Body ground

Always

10 kQ or higher

X1-5 (SGA) - Body ground

Always

10 kQ or higher

REPAIR OR REPLACE HARNESS OR CONNECTOR

REPLACE AIR CONDITIONING AMPLIFIER