Inspection

1. INSPECT CRANKSHAFT POSITION SENSOR

(a) Using an ohmmeter, measure the resistance between the terminals. Standard resistance

Temperature

Specified Condition

Cold

985 to 1,600 Q

Hot

1,265 to 1,890 Q

NOTICE:

"Cold" and "Hot" mean the temperature of the coils themselves. "Cold" is from -10 to 50°C (14 to 122°F) and "Hot" is from 50 to 100°C (122 to 212°F).

If the resistance is not as specified, replace the sensor.