Inspection

1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY

(a) Measure the resistance according to the value(s) in the table below. Standard resistance

Tester Connection

Condition

Specified Condition

5 - 4

OFF

1G kQ or higher

5 - 4

ON

Below 1 Q

If the result is not as specified, replace the hazard warning signal switch assembly. (b) Apply battery voltage to the hazard warning signal switch assembly connector. OK

Measurement Condition

Specified Condition

Battery positive (+) ^ Terminal 7 Battery negative (-) ^ Terminal 8

Illumination comes on

If the result is not as specified, replace the hazard warning signal switch assembly.

DIY Battery Repair

DIY Battery Repair

You can now recondition your old batteries at home and bring them back to 100 percent of their working condition. This guide will enable you to revive All NiCd batteries regardless of brand and battery volt. It will give you the required information on how to re-energize and revive your NiCd batteries through the RVD process, charging method and charging guidelines.