Standard voltage

Tester Connection

Condition

Specified Condition

E11-3 (CLTB) - E11-6 (CLTE)

Ignition switch off

Below 1 V

Ignition switch on (IG)

10 to 14 V

Standard resistance

Tester Connection

Specified Condition

E11-6 (CLTE) - Body ground

Below 1 Q

If the result is not as specified, there may be a malfunction on the wire harness side.

(c) Reconnect the automatic light control sensor connector.

(d) Connect an oscilloscope to the automatic light control sensor connector.

Wire Harness Side:

Automatic Light Control Sensor

CLTE CLTB

B109993E16

(e) Check the waveform. OK

Tester Connection

Tool Setting

Condition

Specified Condition

E11-6 (CLTE) -E11-4 (CLTS)

5 V/DIV., 5 ms./ DIV

Ignition switch on (IG), light control switch in AUTO

Correct waveform is as shown

HINT:

If the ambient light becomes brighter, width A becomes narrower.

If the result is not as specified, replace the automatic light control sensor.