Standard voltage

Tester Connection

Condition

Specified Condition

E14-2 (LR) - Body ground

Hazard warning switch OFF

Below 1 V

E14-2 (LR) - Body ground

Hazard warning switch ON

10 to 14 V (60 to 120 times per minute)

E14-2 (LR) - Body ground

Turn signal switch OFF

Below 1 V

E14-2 (LR) - Body ground

Ignition switch on (IG) and turn signal switch in RH position

10 to 14 V (60 to 120 times per minute)

E14-3 (LL)- Body ground

Hazard warning switch OFF

Below 1 V

E14-3 (LL) - Body ground

Hazard warning switch ON

10 to 14 V (60 to 120 times per minute)

E14-3 (LL) - Body ground

Turn signal switch OFF

Below 1 V

E14-3 (LL) - Body ground

Ignition switch on (IG) and turn signal switch in LH position

10 to 14 V (60 to 120 times per minute)

E14-5 (EL) - Body ground

Ignition switch on (IG) and turn signal switch OFF

10 to 14 V

E14-5 (EL) - Body ground

Ignition switch on (IG) and turn signal switch in LH position

Below 1 V

E14-6 (ER) - Body ground

Ignition switch on (IG) and turn signal switch OFF

10 to 14 V

E14-6 (ER) - Body ground

Ignition switch on (IG) and turn signal switch in RH position

Below 1 V

E14-8 (HAZ) - Body ground

Hazard warning switch OFF

10 to 14 V

E14-8 (HAZ) - Body ground

Hazard warning switch ON

Below 1 V

If the result is not as specified, replace the turn signal flasher assembly.