Inspection Of Light Retractor Relay

1. inspect relay continuity

(a) Check that there is continuity between terminals 1 and 2 and also between terminals 1 and 3.

(b) Check that there is continuity between terminals 4 and 5 and also between terminals 4 and 6.

(c) Check that there is no continuity between terminals3 and 4.

If continuity is not as specified, replace the relay.

Continuity

Continuity

Continuity

Continuity

2. INSPECT RELAY OPERATION

(a) Connect the positive (+} lead from the battery to terminal 3. Connect the negative (-} lead to terminals 1 and 2.

(b) Check the continuity between terminals 3 and 5 and terminals 3 and 6.

If operation is not as specified, replace the relay.

Light Retractor Control Relay

INSPECTION OF LIGHT RETRACTOR CONTROL RELAY

INSPECT RELAY OPERATION

(a) Connect the positive (+) lead from the battery to terminal 5. Connect the negative (-) lead to terminal 1.

(b) Connect the negative (-) lead from the battery to terminal 3. After disconnecting the connection between terminal 3 and battery, check the continuity for 6-14 seconds between terminals 1 and 2.

(c) Check the continuity between terminals 1 and 4 after connecting the negative (-) lead from the battery to terminal 6. After disconnecting the connection between terminal 6 and the battery, check that there is continuity for 2 - 4 seconds between terminals 1 and 4, and continuity immediately for 6 — 14 seconds between terminals 1 and 2.

If operation is not as specified, replace the relay.

Light Retractor Motor

INSPECTION OF LIGHT RETRACTOR MOTOR

1. INSPECT MOTOR OPERATION

Connect the positive (+) lead from the battery to terminal 2 and connect the negative (-) lead to terminal 1. Check that the motor runs.

If there is no motor operation, replace the motor.

INSPECT DIODE CONTINUITY OF MOTOR

(a) Move the headlights to any position except the uppermost or lowermost position.

(b) Connect the ohmmeter positive (+) lead to terminal 4 and the negative (—) lead to terminal 5.

(c) Connect the ohmmeter positive (+) lead to terminal 4 and the negative (-) lead to terminal 3.

If there is no continuity, replace the motor assembly.

No continuity

No continuity

No continuity

No continuity

BC0C*4

(d) Reverse the test leads of the ohmmeter and inspect continuity.

If there is continuity, replace the motor assembly.

Tercel Light Retractor Control RelayFahrzeuge Einfach Ausmalen
beow2

Was this article helpful?

0 0
DIY Battery Repair

DIY Battery Repair

You can now recondition your old batteries at home and bring them back to 100 percent of their working condition. This guide will enable you to revive All NiCd batteries regardless of brand and battery volt. It will give you the required information on how to re-energize and revive your NiCd batteries through the RVD process, charging method and charging guidelines.

Get My Free Ebook


Responses

  • natalino
    Where is toyota supra 1987 retract control relay location?
    1 year ago

Post a comment