PREPARATION:

(a) Disconnect the vacuum hose from the pressure sensor for HC adsober and catalyst system.

(b) Connect the MITYVAC (Hand-held vacuum pump) to the vacuum hose.

(c) Connect the TOYOTA hand-held tester to the DLC3. CHECK:

(a) VSV (for HC adsober and catalyst system) is operate by TOYOTA hand-held tester.

(b) Apply vacuum of 55 kPa (420 mmHg, 16.24 in.Hg).

(c) Check that the vacuum after 30 sec. OK:

The vacuum is 25 Kpa (188 mmHg, 7.38 in.Hg) or more.

Check and replace vacuum hose between intake manifold and actuator.