Check Combination Meter Assembly S Voltage

Wire Harness Side:

(E19 Combination Meter Connector

21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 30 40

A127854E03

(a) Disconnect the E19 combination meter connector.

(b) Turn the ignition switch ON.

(c) Measure the voltage between the terminal of the combination meter and the body ground. Standard voltage

Tester Connections

Specified Conditions

E19-39 (+S) - Body ground

4.5 to 5.5 V

(d) Reconnect the combination meter connector.

Do It Yourself Car Diagnosis

Do It Yourself Car Diagnosis

Don't pay hundreds of dollars to find out what is wrong with your car. This book is dedicated to helping the do it yourself home and independent technician understand and use OBD-II technology to diagnose and repair their own vehicles.

Get My Free Ebook