Check Floor Wire No For Short

a. Release the activation prevention mechanism built into connector "B" (See CHECK MODE PROCEDURE ).

b. Measure the resistance according to the value(s) in the table below. OK

TESTER CONNECTION

SPECIFI]

ED CONDITION CI

Tester Connection

Condition

Specified Condition

P10-1 (PL+) - P10-2 (PL-)

Always

1ART

2007 RESTRAINTS Supplemental Restraint System - Sequoia

2007 RESTRAINTS Supplemental Restraint System - Sequoia

NG: REPAIR OR REPLACE FLOOR WIRE NO.2

4. CHECK FLOOR WIRE NO.2 (FOR OPEN)

a. Measure the resistance according to the value(s) in the table below.

TESTER CONNECTION

SPECIFI]

ED CONDITION CI

Tester Connection

Condition

Specified Condition

P10-1 (PL+) - P10-2 (PL-)

Always

Below 1 ohms

OK: Go to step 11

2007 RESTRAINTS Supplemental Restraint System - Sequoia

NG: REPAIR OR REPLACE FLOOR WIRE NO.2

5. CHECK FLOOR WIRE NO.2 (TO GROUND)

a. Measure the resistance according to the value(s) in the table below.

TESTER CONNECTION SPECIFIED CONDITION CHART

Tester Connection

Condition

Specified Condition

P10-1 (PL+) - Body ground

Always

1 Mohms or higher

P10-2 (PL-) - Body ground

Always

1 Mohms or higher

OK: Go to step 11

2007 RESTRAINTS Supplemental Restraint System - Sequoia

2007 RESTRAINTS Supplemental Restraint System - Sequoia