Brushes

1. INSPECT EXPOSEO BRUSH LENGTH

Using a scale, measure the exposed brush length. Standard exposed length: 10.5 mm (0.413 in.) Minimum exposed length: 1.5 mm (0.059 in.) I7M-GE <M/T)l

If the exposed length is less than minimum, replace the brushes.

If the exposed length is less than minimum, replace the brush holder.

IF NECESSARY, REPLACE BRUSHES

(a) Unsolder and remove the brush and spring.

(b) Run wire of the brush through the hole in the brush holder, and insert the spring and brush into the brush holder.

Ohmmeter

(c) Solder the brush wire to the brush holder at the exposed length.

(d) Check that the brush moves smoothly in the brush holder.

(e) Cut off the excess wire.

(f) Apply insulation paint to the soldered point.

Was this article helpful?