Inspect Negative Side Rectifier

(a) Connect one tester probe to each rectifier terminal and the other to each rectifier negative ( —) terminal.

Ohmmeter

CSD

1-

i—j

\e /

CHOMA

(b) Reverse the polarity of the tester probes.

(c) Check that one shows continuity and the other shows no continuity.

If not. replace the rectifier holder.