Inspect Efirelay

(a) Check the resistance.

(1) Using an ohmmeter, measure the resistance between the terminals. Standard

Tester Connection

Specified Condition

3 - 5

10 kQ or higher

3 - 5

Below 1 Q (Apply battery voltage to terminals 1 and 2)

If the result is not as specified, replace the EFI relay.

A098613E02

CIRCUIT OPENING RELAY INSPECTION

DIY Battery Repair

DIY Battery Repair

You can now recondition your old batteries at home and bring them back to 100 percent of their working condition. This guide will enable you to revive All NiCd batteries regardless of brand and battery volt. It will give you the required information on how to re-energize and revive your NiCd batteries through the RVD process, charging method and charging guidelines.