Standard Resistance Check for open

1

2

3

4

5

ECM Connector

KNK1

EKN2 EKNK

Tester Connections

Specified Conditions

EE1 female connector 2 - KNK1 (E5-29)

Below 1 Q

EE1 female connector 5 - EKNK (E5-28)

EE1 female connector 4 - KNK2 (E5-21)

EE1 female connector 6 - EKN2 (E5-20)

Standard Resistance (Check for short)

Tester Connections

Specified Conditions

EE1 female connector 2 or KNK1 (E5-29) - Body ground

10 kQ or higher

EE1 female connector 5 or EKNK (E5-28) - Body ground

EE1 female connector 4 or KNK2 (E5-21) - Body ground

EE1 female connector 6 or EKN2 (E5-20) - Body ground

(d) Reconnect the EE1 connector.

(e) Reconnect the ECM connector.