Standard Resistance Check for open

Tester Connections

Specified Conditions

+B (M1-1) - EFI relay (3)

Below 1 Q

Standard Resistance (Check for short)

Tester Connections

Specified Conditions

+B (M1-1) or EFI relay (3) - Body ground

10 kQ or higher

(e) Reconnect the MAF meter connector.

(f) Reinstall the EFI relay.

Do It Yourself Car Diagnosis