Typical Enabling Conditions

Monitor runs whenever following DTCs not present

P0100 - P0103 (MAF meter)

P0115 - P0118 (ECT sensor)

P0125 (Insufficient ECT for closed loop)

P0335 (CKP sensor)

P0340 (CMP sensor)

P0351 - P0354 (Igniter)

Battery voltage

11 V or more

Throttle position learning

Completed

Engine RPM

550 to 4,000 rpm

Engine coolant temperature

70 to 100°C (167 to 212°F)

TYPICAL MALFUNCTION THRESHOLDS

Advance:

Both of the following conditions are met

-

(a) Deviation of valve timing

More than 5° CA (crankshaft angle)

(b) Valve timing

No change at advanced valve timing

Retarded:

Both of the following conditions are met

-

(a) Deviation of valve timing

More than 5° CA (crankshaft angle)

(b) Valve timing

No change at retarded valve timing

If the difference between the target and actual camshaft timings is greater than the specified value, the

ECM operates the VVT (Variable Valve Timing) actuator.

Then, the ECM monitors the camshaft timing change for 5 seconds.