Inspect Iac Valve Operation

(a) Connect the positive (+) lead form the battery to terminal +B and negative (-) lead to terminal RSC, and check that the valve is closed.

(b) Connect the positive (+) lead from the battery to terminal +B and negative (-) lead to terminal RSO, and check that the valve is open. If operation is not as specified, replace the IAC valve.

INSTALLATION

Installation is in reverse order of removal (See page MF-35).