Inspect Integration Relay Operation

(a) Connect the positive (+) lead from the battery to terminal 3.

(b) Connect the negative (-) lead from the battery to terminals 7 and 11.

(c) Check that the bulb lights and the chime sounds for 4 -8 seconds.

(d) Return to step (a), and operate the chime again.

(e) Connect the positive (+) lead from the battery to terminal 9.

(f) Check that the chime stops sounding. HINT:

Check the chime within a period of 4 to 8 seconds. If operation is not as specified, replace the relay. 10. INSPECT INTEGRATION RELAY CIRCUIT (See page BE-11)