Inspect No Cooling Fan Relay

(a) Remove the relay box cover.

(b) Remove the No.2 cooling fan relay (Marking: FAN NO.2).

(c) Inspect the No.2 cooling fan relay continuity.

(1) Using an ohmmeter, check that there is continuity between terminals 85 and 86.

If there is no continuity, replace the relay.

(2) Check that there is continuity between terminals 30 and 87a.

If there is no continuity, replace the relay.

(3) Check that there is no continuity between terminals 30 and 87.

If there is continuity, replace the relay.

(d) Inspect the No.2 cooling fan relay operation.

(1) Apply battery voltage across terminals 85 and 86.

(2) Using an ohmmeter, check that there is no continuity between terminals 30 and 87.

If there is continuity, replace the relay.

(3) Using an ohmmeter, check that there is continuity between terminals 30 and 87.

If there is no continuity, replace the relay.

(e) Reinstall the No.2 cooling fan relay.

DIY Battery Repair

DIY Battery Repair

You can now recondition your old batteries at home and bring them back to 100 percent of their working condition. This guide will enable you to revive All NiCd batteries regardless of brand and battery volt. It will give you the required information on how to re-energize and revive your NiCd batteries through the RVD process, charging method and charging guidelines.