Inspect Outer Rear View Mirror Assembly Imi Lh

(a) Check the operation.

(1) Apply battery voltage to the outer rear view mirror and check the operation of the outer rear view mirror. Standard

Measurement Condition

Mirror Assembly Operation

Battery positive (+) - Terminal 5 (MV) Battery negative (-) - Terminal 4 (COM)

Turns upward

Battery negative (-) - Terminal 5 (MV)

Turns downward

Battery positive (+) - Terminal 3 (MH) Battery negative (-) - Terminal 4 (COM)

Turns left

Battery negative (-) - Terminal 3 (MH)

Turns right

If the result is not as specified, replace the outer rear view mirror.

Was this article helpful?

0 0
DIY Battery Repair

DIY Battery Repair

You can now recondition your old batteries at home and bring them back to 100 percent of their working condition. This guide will enable you to revive All NiCd batteries regardless of brand and battery volt. It will give you the required information on how to re-energize and revive your NiCd batteries through the RVD process, charging method and charging guidelines.