Replacement

NOTICE:

When recharging refrigerant, collect together all the refrigerant remaining in the cycle, then recharge and seal the refrigerant as described below. (Do not overcharge.)

1. DISCHARGE REFRIGERANT FROM

REFRIGERATION SYSTEM

(a) Start up the engine.

(c) Turn the blower switch to ON.

(d) Operate the cooler compressor with an engine speed of approximately 1,000 rpm for 5 to 6 minutes to circulate the refrigerant and collect the remaining compressor oil from each component, in the cooler compressor.

(e) Stop the engine.

(f) Remove the caps from the service valves on the

Yaris Refrigerant

refrigerant line.

(g) Connect the Freon collection/recycling device to discharge the refrigerant gas remaining in the refrigeration system.

NOTICE:

Use the Freon collection/recycling device in accordance with the manufacturer's instruction manual.

2. CHARGE REFRIGERANT

SST 07110-58060 (07117-58080, 07117-58090, 07117-78050, 07117-88060, 07117-88070,

07117-88080)

I101550E01

NOTICE:

Charge refrigerant in accordance with equipment manual.

(a) Perform vacuum purging using a vacuum pump.

(b) Charge refrigerant HFC-134a (R134a). Standard:

NOTICE:

Do not start the engine before charging it with refrigerant as the cooler compressor doesn't work properly without sufficient refrigerant. This could cause the compressor to overheat.

HINT:

• The relationship between refrigerant charge amount and pressure is as follows.

If refrigerant is overcharged, pressure rises on the high-pressure side. High-pressure cut off frequently occurs. This causes insufficient cooling performance and also insufficient compressor lubrication.

Shortage of refrigerant causes insufficient cooling performance and low circulation of refrigerant oil, which shortens compressor life. Operation with insufficient coolant raises refrigerant temperature and causes heat deterioration of rubber seals and hoses. Cracking and thus refrigerant leakage may occur. (1) Install the caps onto the service valves on the refrigerant line.

3. WARM UP ENGINE NOTICE:

Warm up the engine at less than 2,000 rpm for 1 minute or more after charging it with refrigerant.

4. CHECK FOR REFRIGERANT LEAKAGE

(a) After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.

(b) Perform the operation as follows:

• Secure good ventilation (the halogen leak detector may react to volatile gases other than refrigerant, such as evaporated gasoline or exhaust gas).

• Make sure that some refrigerant remains in the refrigeration system.

When compressor is off: approximately 392 to

It is impossible for the above pressure to be maintained if there is leakage.

(c) Using the halogen leak detector, check the refrigerant line, especially the connection points, for leakage.

Yaris Aircon Drain Tube

(d) Bring the halogen leak detector close to the drain hose before performing the test.

HINT:

• After the blower motor has stopped, leave the cooling unit for at least 15 minutes.

• Place the halogen leak detector sensor under the drain hose.

• When bringing the halogen leak detector close to the drain hose, make sure that the halogen leak detector does not react to the volatile gases.

If such a reaction is unavoidable, the vehicle must be lifted up.

(e) If a gas leak is not detected from the drain hose, remove the blower motor from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.

(f) Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.

Waste Management And Control